Precautions For Correct Use - Omron RX Series User Manual

High-function general-purpose inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

• Do not short + and –, charge, disassemble, heat, put into the fire, or apply strong impact on the
battery. The battery may leak, explode, produce heat, or fire. Never use the battery which was
applied strong impact due to such as fall on the floor, it may leak.
• UL standards establish that the battery shall be replaced by an expert engineer. The expert engineer
must be in charge of the replacement and also replace the battery according to the method described
in this manual.
• When the display of LCD Digital Operator cannot be recognized due to the service life, replace the
LCD digital operator.

Precautions for Correct Use

Operation Stop Command
• Provide a separate emergency stop switch because the STOP Key on the Operator is valid only when
function settings are performed.
• When checking a signal during the power supply and the voltage is erroneously applied to the control
input terminals, the motor may start abruptly. Be sure to confirm safety before checking a signal.
Maintenance and Parts Replacement
• Inverters contain components and will operate properly only when each component operates
normally. Some of the electrical components require maintenance depending on application
conditions. Periodic inspection and replacement are necessary to ensure proper long-term operation
of Inverters. (Quoted from The Recommendation for Periodic Maintenance of a General-purpose
Inverter published by JEMA.)
• When a cooling fan reaches the end of its service life, replace it.
Product Disposal
• Comply with the local ordinance and regulations when disposing of the product.
High-function General-purpose Inverter 3G3RX-V1 User's Manual (SBCE-367)
11 Maintenance and Inspection
11
11 - 3

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents