Command 03
Reads all monitor data.
• Transmission Frame
Frame format
STX
STX
Control code (Start of Text)
Station
Station No. of target Inverter
No.
Command Transmission command
BCC
Block check code
CR
Control code (Carriage Return)
• Response frame
Frame format
STX
STX
Control code (Start of Text)
Station
Station No. of target Inverter
No.
Data
Data
BCC
Block check code
CR
Control code (Carriage Return)
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Station
Command
BCC
No.
Description
Station
Data
BCC
No.
Description
8 Communications Functions
CR
Data size
1 byte
STX (0x02)
2 bytes
01 to 32
2 bytes
03
Exclusive OR of frame segments from
2 bytes
Station No. to Data (Refer to page 8-94.)
1 byte
CR (0x0D)
CR
Data size
1 byte
STX (0x02)
2 bytes
01 to 32
104 bytes
* (Refer to the next page.)
Exclusive OR of frame segments from
2 bytes
Station No. to Data (Refer to page 8-94.)
1 byte
CR (0x0D)
Setting
Setting
8 - 83