8 Communications Functions
Command 08
Restores all parameters to the default datas.
The function of this command depends on the value set in the Initialization Selection (b084). If b084 is
set to 00, the trip data will be cleared.
• Transmission Frame
Frame format
STX
STX
Control code (Start of Text)
Station
Station No. of target Inverter
No.
Command Transmission command
BCC
Block check code
CR
Control code (Carriage Return)
• Response frame
Positive response: Refer to page 8-92
Negative response: Refer to page 8-93
Command 09
Checks if a set value can be stored in EEPROM.
• Transmission Frame
Frame format
Station
STX
No.
STX
Control code (Start of Text)
Station
Station No. of target Inverter
No.
Command Transmission command
BCC
Block check code
CR
Control code (Carriage Return)
8 - 90
Station
Command
BCC
No.
Description
Command
BCC
Description
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
CR
Data size
1 byte
STX (0x02)
2 bytes
01 to 32, FF (Broadcast to all stations)
2 bytes
08
Exclusive OR of frame segments from
2 bytes
Station No. to Data (Refer to page 8-94.)
1 byte
CR (0x0D)
CR
Data size
1 byte
STX (0x02)
2 bytes
01 to 32
2 bytes
09
Exclusive OR of frame segments from
2 bytes
Station No. to Data (Refer to page 8-94.)
1 byte
CR (0x0D)
Setting
Setting