 Output terminal
Terminal
Terminal
symbol
AP
Encoder
AN
signal
BP
output
BN
EP5
Encoder
EG5
power
supply
(Common)
DIP switch name
SWENC
*1
SWR
*1. To input the pulse train position command into more than one inverter, set the DIP switches SWR1 and SWR2
to ON only one inverter that is farthest from the master.
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Functional description
name
Output pulses in a ratio 1 to 1 to encode
input pulses.
+5 VDC power supply
Switch No.
ON
1
OFF
ON
2
OFF
ON
1
OFF
ON
2
OFF
5 VDC line-driver output
(RS-422 compliant)
150 mA max.
Description
Disconnection detection enabled when the
encoder phase A/B is not connected
Disconnection detection disabled when the
encoder phase A/B is not connected
Disconnection detection enabled when the
encoder phase Z is not connected
Disconnection detection disabled when the
encoder phase Z is not connected
Built-in terminating resistor between SAP and
SAN enabled (150 Ω)
Built-in terminating resistor between SAP and
SAN disabled
Built-in terminating resistor between SBP and
SBN enabled (150 Ω)
Built-in terminating resistor between SBP and
SBN disabled
2 Design
Electrical specifications
Default
data
OFF
OFF
OFF
OFF
2 - 51