5 Basic Settings
Parameter
No.
name
Overload
0.20 x Heavy-load rated
b022
Limit Level
current to 2.00 x Heavy-load
rated current [A] (0.20 x
Heavy-load rated current to
Overload
b025
1.80 x Heavy-load rated
Limit Level 2
current [A]
0.20 x Heavy-load rated
current to 2.00 x Heavy-load
Frequency
rated current [A] (0.20 x
b028
Pull-in
Heavy-load rated current to
Restart Level
1.80 x Heavy-load rated
current [A])
Torque Limit 1
(Four-quadrant
b041
Mode Forward
Power
Running)
Torque Limit 2
(Four-quadrant
b042
Percentage of heavy-load
Mode Reverse
rated current
Regeneration)
0. to 200.[%] (0. to 180.[%])
Torque Limit 3
(Four-quadrant
no: Function disabled
b043
Mode Reverse
Power
Running)
Torque Limit 4
(Four-quadrant
b044
Mode Forward
Regeneration)
Carrier
0.5 to 15.0 [kHz] (0.5 to 10.0
b083
Frequency
[kHz])
Digital
Current
0.20 x Heavy-load rated
C030
Monitor
current to 2.00 x Heavy-load
Reference
rated current [A]
Value
0.00 x Heavy-load rated
current to 2.00 x Heavy-load
Low Current
rated current [A] (0.00 x
C039
Detection
Heavy-load rated current to
Level
1.80 x Heavy-load rated
current [A])
0.00 x Heavy-load rated
current to 2.00 x Heavy-load
rated current [A] (0.00 x
Overload
Heavy-load rated current to
C041
Warning
1.80 x Heavy-load rated
Level
current [A])
0.00: Function disabled
5 - 14
Setting range
Heavy load (CT)
0.20 x Light-load rated
current to 1.50 x Light-load
rated current [A] (0.20 x
Light-load rated current to
1.50 x Light-load rated
current [A])
0.20 x Light-load rated
current to 1.50 x Light-load
rated current [A] (0.20 x
Light-load rated current to
1.50 x Light-load rated
current [A])
Percentage of light-load
rated current
0. to 150.[%] (0. to 150.[%])
no: Function disabled
0.5 to 12.0 [kHz] (0.5 to 8.0
[kHz])
0.20 x Light-load rated
current to 1.50 x Light-load
rated current [A]
0.00 x Light-load rated
current to 1.50 x Light-load
rated current [A] (0.00 x
Light-load rated current to
1.50 x Light-load rated
current [A])
0.00 x Light-load rated
current to 1.50 x Light-load
rated current [A] (0.00 x
Light-load rated current to
1.50 x Light-load rated
current [A])
0.00: Function disabled
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Default data
Heavy load
Light load (VT)
(CT)
1.50 x
Heavy-load
rated
current [A]
Heavy-load
rated
current [A]
150.[%]
5.0 [kHz]
(3.0 [kHz])
Heavy-load
rated
current [A]
Heavy-load
rated
current [A]
Heavy-load
rated
current [A]
Initialization at
mode switching
Light load
Heavy
Light to
(VT)
to Light
Heavy
1.20 x
Light-load
Conversion
Enabled
rated
*1
current [A]
Light-load
Conversion
rated
Enabled
*1
current [A]
120.[%]
Enabled
Disabled
3.0 [kHz]
Enabled
Disabled
(3.0 [kHz])
Light-load
Conversion
rated
Enabled
*1
current [A]
Light-load
Conversion
rated
Enabled
*1
current [A]
Light-load
Conversion
rated
Enabled
*1
current [A]