8 Communications Functions
Modbus
Register
register
No.
spec. No.
0030 hex
002F hex
Fault Monitor 4 Factor
Fault Monitor 4 Inverter
0031 hex
0030 hex
Status
Fault Monitor 4 Output
0032 hex
0031 hex
Frequency (HIGH)
Fault Monitor 4 Output
0033 hex
0032 hex
Frequency (LOW)
Fault Monitor 4 Output
0034 hex
0033 hex
Current
Fault Monitor 4 Main Circuit
0035 hex
0034 hex
DC Voltage
Fault Monitor 4 Total RUN
0036 hex
0035 hex
Time (HIGH)
Fault Monitor 4 Total RUN
0037 hex
0036 hex
Time (LOW)
Fault Monitor 4 Total Power
0038 hex
0037 hex
ON Time (HIGH)
Fault Monitor 4 Total Power
0039 hex
0038 hex
ON Time (LOW)
003A hex
0039 hex
Fault Monitor 5 Factor
Fault Monitor 5 Inverter
003B hex
003A hex
Status
Fault Monitor 5 Output
003C hex
003B hex
Frequency (HIGH)
Fault Monitor 5 Output
003D hex
003C hex
Frequency (LOW)
Fault Monitor 5 Output
003E hex
003D hex
Current
Fault Monitor 5 Main Circuit
003F hex
003E hex
DC Voltage
Fault Monitor 5 Total RUN
0040 hex
003F hex
Time (HIGH)
Fault Monitor 5 Total RUN
0041 hex
0040 hex
Time (LOW)
Fault Monitor 5 Total Power
0042 hex
0041 hex
ON Time (HIGH)
Fault Monitor 5 Total Power
0043 hex
0042 hex
ON Time (LOW)
Note 1 The inverter's rated current is 1,000.
2 When the set value is 10,000 (100.0 s) or more, the value in the second decimal place is ignored.
8 - 30
Parameter
Function name
No.
d084
d085
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
R/W
Monitor or setting data
Refer to Inverter Fault Monitor
Factor List on page 8-34.
Refer to Inverter Fault Monitor
Factor List on page 8-34.
0 to 40000
Output current value at the time
of trip
R
DC input voltage at the time of
trip
Total RUN time before the trip
Total power ON time before the
trip
Refer to Inverter Fault Monitor
Factor List on page 8-34.
Refer to Inverter Fault Monitor
Factor List on page 8-34.
0 to 40000
Output current value at the time
of trip
R
DC input voltage at the time of
trip
Total RUN time before the trip
Total power ON time before the
trip
Resolution
0.01 [Hz]
0.1 [A]
1 [V]
1 [h]
1 [h]
0.01 [Hz]
0.1 [A]
1 [V]
1 [h]
1 [h]

Hide quick links: