Omron RX Series User Manual page 290

High-function general-purpose inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

6 Vector Control
Precautions for Correct Use
Precautions for Correct Use
• To operate the inverter with the auto-tuned data after normal completion of auto-tuning, be
sure to change the 1st Motor Parameter selection (H002) setting to 01.
• Adjust the DC Injection Braking Selection (A051) and Output Voltage Gain (A045) values
according to the user environment.
Parameter No.
H002
H030
H031
H032
H033
H034
A045
A051
5
Operations in case of error
If auto-tuning is aborted by an error, review the preset parameters and check the rated motor
torque ratio of the inverter to that of the motor. If the load is too heavy, disconnect the load and
retry auto-tuning.
If the error persists or auto-tuning is still aborted, enter the motor parameter values directly.
For details, refer to 6-2-4 Motor Parameter Settings on page 6-11.
6 - 22
Function name
1st Motor Parameter
selection
1st Motor Parameter R1
(Auto-tuning Data)
1st Motor Parameter R2
(Auto-tuning Data)
1st Motor Parameter L
(Auto-tuning Data)
1st Motor Parameter lo
(Auto-tuning Data)
1st Motor Parameter J
(Auto-tuning Data)
Output Voltage Gain
DC Injection Braking
Selection
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Data
00: Standard motor parameter
01: Auto-tuning
02: Auto-tuning (Online auto-tuning
enabled)
0.001 to 9.999
10.00 to 65.53
0.01 to 99.99
100.0 to 655.3
0.001 to 9.999
10.00 to 99.99
100.0 to 999.9
1000. to 9999.
20. to 100.
00: Disabled
01: Enabled
02: Enabled (Operates only at set
frequency)
Default data
Unit
00
Ω
mH
Dependent
on motor
A
capacity
2
kg/m
100.
%
00