* Multi-function terminal setting data (hexadecimal) and descriptions
(For details, refer to Multi-function Input Selection on page 7-108.)
Data [hex]
0000000000000001
FW : Forward
0000000000000002
RV : Reverse
0000000000000004
CF1 : Multi-step speed setting binary 1
0000000000000008
CF2 : Multi-step speed setting binary 2
0000000000000010
CF3 : Multi-step speed setting binary 3
0000000000000020
CF4 : Multi-step speed setting binary 4
0000000000000040
JG
0000000000000080
DB : External DC injection braking
0000000000000100
SET : 2nd control
0000000000000200
2CH : 2-step acceleration/deceleration
0000000000000400
0000000000000800
FRS : Free-run stop
0000000000001000
EXT : External trip
0000000000002000
USP : Power recovery restart prevention
0000000000004000
CS : Commercial switch
0000000000008000
SFT : Soft lock
0000000000010000
AT
0000000000020000
SET3: 3rd control
0000000000040000
RS : Reset
0000000000080000
0000000000100000
STA : 3-wire start
0000000000200000
STP : 3-wire stop
0000000000400000
F/R : 3-wire forward/reverse
0000000000800000
PID : PID enabled/disabled
0000000001000000
PIDC: PID integral reset
0000000002000000
0000000004000000
CAS : Control gain switching
0000000008000000
UP : Remote operation acceleration
0000000010000000
DWN: Remote operation deceleration
0000000020000000
UDC : UP/DWN function data clear
0000000040000000
0000000080000000
OPE : Forced Operator
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Description
: Jogging
: Analog input switching
8 Communications Functions
Data [hex]
0000000100000000
SF1 : Multi-step speed setting bit 1
0000000200000000
SF2 : Multi-step speed setting bit 2
0000000400000000
SF3 : Multi-step speed setting bit 3
0000000800000000
SF4 : Multi-step speed setting bit 4
0000001000000000
SF5 : Multi-step speed setting bit 5
0000002000000000
SF6 : Multi-step speed setting bit 6
0000004000000000
SF7 : Multi-step speed setting bit 7
0000008000000000
OLR : Overload limit switching
0000010000000000
TL
0000020000000000
TRQ1: Torque limit switching 1
0000040000000000
TRQ2: Torque limit switching 2
0000080000000000
PPI : P/PI switching
0000100000000000
BOK : Brake confirmation
0000200000000000
ORT : Orientation
0000400000000000
LAC : LAD cancel
0000800000000000
PCLR: Position deviation clear
0001000000000000
STAT: Pulse train position command permission
0002000000000000
0004000000000000
ADD : Set frequency addition
0008000000000000
F-TM: Forced terminal
0010000000000000
ATR : Torque command input permission
0020000000000000
KHC : Integrated power clear
0040000000000000
SON : Servo ON
0080000000000000
FOC : Preliminary excitation
0100000000000000
MI1 : Not used
0200000000000000
MI2 : Not used
0400000000000000
MI3 : Not used
0800000000000000
MI4 : Not used
1000000000000000
MI5 : Not used
2000000000000000
MI6 : Not used
4000000000000000
MI7 : Not used
8000000000000000
MI8 : Not used
Description
: Torque limit enabled/disabled