Omron RX Series User Manual page 317

High-function general-purpose inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

 Low-speed Origin Search (P068 = 00: Origin Search Mode 1)
ORG Terminal
ORL Terminal
Output
Frequency
 High-speed Origin Search 1 (P068 = 01: Origin Search Mode 2)
ORG Terminal
ORL Terminal
Output
Frequency
 High-speed Origin Search 2 (P068 = 02: Origin Search Mode 3)
ORG Terminal
ORL Terminal
Output
Frequency
Z pulse
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
ON
(b)
Origin Search Mode 1
Frequency (P070)
(c)
(a)
Origin
ON
(b)
(c)
(a)
Origin
(d)
(e)
Origin Search Mode 1
Frequency (P070)
ON
(b)
Origin Search Mode 2
Frequency (P071)
(c)
(a)
(f)
(e)
(d)
Origin Search Mode 1
Frequency (P070)
ON
Position
ON
Origin Search Mode 2
Frequency (P071)
Position
ON
Origin Search Mode 1
Frequency (P070)
(g)
Origin
Position
6 Vector Control
(a) Accelerates to Origin
Search Mode 1 Frequency
according to Acceleration
Time settings.
(b) Runs at Origin Search
Mode 1 Frequency.
(c) Performs positioning when
ORL signal is input.
(a) Accelerates to Origin
Search Mode 2 Frequency
according to Acceleration
Time settings.
(b) Runs at Origin Search
Mode 2 Frequency.
(c) Starts deceleration when
ORL signal turns ON.
(d) Runs in reverse at Origin
Search Mode 1 Frequency.
(e) Performs positioning when
the ORL signal turns OFF.
(a) Accelerates to Origin
Search Mode 2 Frequency
according to Acceleration
Time settings.
(b) Runs at Origin Search
Mode 2 Frequency.
(c) Starts deceleration when
ORL signal turns ON.
(d) Runs in reverse at Origin
Search Mode 1 Frequency.
(e) Starts deceleration when
ORL signal turns OFF.
(f) Runs forward at Origin
Search Mode 1 Frequency.
(g) Performs positioning to
first Z-pulse position after
ORL signal turns ON.
6 - 49
6

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents