User Parameter Automatic Setting Function - Omron RX Series User Manual

High-function general-purpose inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

Initial Screen Selection (Initial Screen after Power-on)
Use the Initial Screen Selection parameter to select from the following the screen that appears on the
Digital Operator at power-ON.
By factory default, this is set to 001 (d001).
Parameter No.
b038

User Parameter Automatic Setting Function

• Setting the User Parameter Automatic Setting Function (b039) to 01 (Enabled) causes the inverter to
store automatically the parameters whose data have been changed in an ascending order from U001
to U012. This function is useful to keep track of changes made to the default datas.
• Parameter changes are stored when the Enter key is pressed. This is also true for the monitor
functions (d***).
• U001 stores the most recent parameter data; U012 stores the oldest.
• The same parameter will be stored only once. In addition, attempting to store more than 12 user
parameter data results in erasing the data from the oldest (U012).
Parameter No.
b039
Related functions
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Function name
000: Screen on which the Enter key
001 to 060: d001 to d060
Initial Screen Selection
201: F001
202: Do not set.
Function name
User Parameter
00: Disabled
Automatic Setting
01: Enabled
Function
U001 to U012
Data
was last pressed
Data
7 Detailed Functions
Default data
Unit
001
Default data
Unit
00
7 - 81
7