Arrangement and Function of Main Circuit Terminal Block

The table below shows the arrangement of the main circuit terminal block and description of each
terminal.
Main Circuit Terminal Block
R/L1
G
Terminal
symbol
R/L1
Main power supply input
S/L2
terminal
T/L3
U/T1
V/T2
Inverter output terminal
W/T3
+1
External DC reactor terminal
P/+2
P/+2
Braking resistor connection
terminal
RB
P/+2
Regenerative braking unit
connection terminal
N/–
G
Ground terminal
Ro
Control circuit power supply
terminal
To
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
Charge indicator
S/L2
T/L3
+1
P/+2
Ground terminal with short-circuit
bar (shaded area) for EMC filter
function switching
Terminal name
Connect the input power supply.
200-V class: 170 to 264 VAC, 50/60 Hz ±5%
400-V class: 323 to 528 VAC, 50/60 Hz ±5%
Connect a 3-phase motor.
The maximum output voltage depends on the input power supply
voltage.
200-V class: 170 to 264 VAC
400-V class: 323 to 528 VAC
Remove the short-circuit bar between the terminals +1 and P/+2,
and connect the optional power factor improvement DC reactor.
Connect optional external braking resistors. The terminal RB is
provided for the inverters with 22 kW or lower capacity.
Connect optional regenerative braking units.
The inverter's ground terminal. Connect this terminal to the
ground.
Class D (200-V class), Class C (400-V class)
Power supply terminals for inverter control circuit.
Ro
To
RB
N/-
U/T1
V/T2
W/T3
+1–P/+2 short-circuit bar
When not using the DC
reactor, keep the
+1–P/+2 short-circuit bar
attached.
Description
2 Design
G
2 - 15
2