Omron RX Series User Manual page 564

High-function general-purpose inverter
Hide thumbs Also See for RX Series:
Table of Contents

Advertisement

8 Communications Functions
Command 06
Reads a parameter setting.
• Transmission Frame
Frame format
STX
STX
Station No.
Command
Parameter
BCC
CR
*1 All parameters can be read, except for F001 and U001 to U012.
• Response frame
Positive response
Frame format
STX
STX
Control code (Start of Text)
Station
Station No. of target Inverter
No.
ACK
Control code (ACKnowledge)
Data
Data (Decimal ASCII code)
BCC
Block check code
CR
Control code (Carriage Return)
8 - 88
Station No. Command
Parameter
Description
Control code (Start of Text)
Station No. of target Inverter
Transmission command
Parameter number for data
Block check code
Control code (Carriage Return)
Station
ACK
Data
No.
Description
High-function General-purpose Inverter 3G3RX-V1 User's Manual (I578-E1)
BCC
CR
Data size
1 byte
STX (0x02)
2 bytes
01 to 32
2 bytes
06
4 bytes
*1
Exclusive OR of frame segments from
2 bytes
Station No. to Data (Refer to page 8-94.)
1 byte
CR (0x0D)
BCC
CR
Data size
1 byte
STX (0x02)
2 bytes
01 to 32
1 byte
ACK (0x06)
8 bytes
*(Refer to the next page.)
Exclusive OR of frame segments from
2 bytes
Station No. to Data (Refer to page 8-94.)
1 byte
CR (0x0D)
Setting