Hard disk drives / solid state drives
7.1.3
Removing a 2.5-inch HDD/SSD module
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Follow the safety instructions in chapter
page
43.
V
Only applicable for removing non-defective HDD/SSD modules:
Ê Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD/SSD module that is
not defective.
7.1.3.1
Required tools
Preliminary and concluding steps: tool-less
●
Main steps: tool-less
●
7.1.3.2
Preliminary steps
Ê Perform the following procedures:
1. Ensure that the HDD/SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete
the array using ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
I
For further information, please refer to the "ServerView Suite
RAID Management" user guide, available online at
http://manuals.ts.fujitsu.com
http://jp.fujitsu.com/platform/server/primergy/manual/
market) or from the ServerView Suite DVD 2 supplied with your
PRIMERGY server.
2.
"Opening the rack door" on page 59
150
Upgrade and Maintenance Manual
"Important information" on
(EMEA market) or
(Japanese
RX100 S7