Replacing A 2.5-Inch Hdd/Ssd Module; Required Tools - Fujitsu PRIMERGY RX100 S7 Upgrade And Maintenance Manual

Server
Hide thumbs Also See for PRIMERGY RX100 S7:
Table of Contents

Advertisement

7.1.4

Replacing a 2.5-inch HDD/SSD module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see "RX100 S7 Server -
Operating Manual".
Under no circumstances should you remove an HDD/SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
Follow the safety instructions in chapter
page
43.
V
Only applicable for removing non-defective HDD/SSD modules:
Ê Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD/SSD module that is
not defective.
7.1.4.1

Required tools

Preliminary and concluding steps: tool-less
Main steps: tool-less
RX100 S7
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
"Important information" on
153