System Board; Replacing The System Board - Fujitsu PRIMERGY RX100 S7 Upgrade And Maintenance Manual

Server
Hide thumbs Also See for PRIMERGY RX100 S7:
Table of Contents

Advertisement

System board and components
15.4

System board

15.4.1 Replacing the system board

Field Replaceable Units (FRU)
Additional task duration for OS and FW Flash: 10 minutes
I
Please note that manual save or restore of BIOS settings might
take more time (up to 25 minutes).
Average task duration: 40 minutes
Note on system information backup / restore
I
The front panel module contains the Chassis ID EPROM that contains
system information like server name and model, housing type, serial
number and manufacturing data.
To avoid the loss of non-default settings when replacing the system
board, a backup copy of important system configuration data is
automatically stored from the system board NVRAM to the Chassis ID
EPROM. After replacing the system board the backup data is restored
from the Chassis ID board to the new system board.
V
CAUTION!
– For that reason the front panel module and system board must not be
replaced simultaneously! In this case, restoring the system
configuration data on the system board would fail.
– The system information won't be restored automatically after
replacing the faulty system board with old BIOS versions. If possible,
please note down all current BIOS settings before replacing. For
details please refer to section
374
Upgrade and Maintenance Manual
"Preliminary steps" on page
376.