Sliding the server into the rack
Figure 11: Sliding the server into the rack
Ê Release the locking mechanism of both rails (1).
Ê Push the server as far as it will go into the rack (2) until the quick-release
levers engage (3).
V
CAUTION!
Be careful with your fingers. You can pinch them when the quick-
release levers change to the release position.
Connecting the cables
Ê Reconnect all the cables you disconnected beforehand on the rear of the
server.
Ê Connect all power cords to the power outlets.
I
To provide true phase redundancy, the second power supply module
should be connected to a different AC power source from the other
supply module. If one AC power source should fail, the server will still
continue to run.
Ê Ensure that the status indicator on the PSU module is lit green.
I
For more information see section
modules" on page
RX100 S7
458.
Upgrade and Maintenance Manual
Basic hardware procedures
"Status indicators on power supply
69