Required Tools; Preliminary Steps; Removing The Tpm - Fujitsu PRIMERGY RX100 S7 Upgrade And Maintenance Manual

Server
Hide thumbs Also See for PRIMERGY RX100 S7:
Table of Contents

Advertisement

System board and components

15.3.3.1 Required tools

Preliminary and concluding steps: Phillips PH2 / (+) No. 2 screw driver
Removing the system board:
– Phillips PH2 / (+) No. 2 screw driver
Replacing the TPM:
– Bit screw driver
– TPM bit insert (*)
– Thin slotted screw driver (2 x 0.4 mm) (*)
(*) For the Japanese market:
– Dedicated TPM screw driver (CWZ8291A)
– TPM module fixing tool (S26361-F3552-L909)

15.3.3.2 Preliminary steps

Ê Perform the following procedures:
1.
"Opening the rack door" on page 59
2.
"Locating the defective server" on page 55
3.
"Disabling BitLocker functionality" on page 75
4.
"Shutting down the server" on page 59
5.
"Extending/removing the server from the rack" on page 60
6.
"Opening the server" on page 64
7.
"Removing the system board" on page 378

15.3.3.3 Removing the TPM

Ê Remove the TPM as described in section
Ê Leave the TPM spacer on the system board when removing the defective
TPM.
372
Upgrade and Maintenance Manual
"Removing the TPM" on page
367.
RX100 S7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents