Hard disk drives / solid state drives
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
All HDD modules (drives) must be uniquely identified so that they can
●
be reinstalled in their original bays later. If this is not done, existing
data can be lost.
Follow the safety instructions in chapter
●
page
43.
V
Only applicable for removing non-defective HDD modules:
Ê Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD module that is not
defective.
7.2.4.1
Required tools
Preliminary and concluding steps: tool-less
●
Main steps: tool-less
●
7.2.4.2
Preliminary steps
Ê Perform the following procedures:
1.
"Opening the rack door" on page 59
2.
"Locating the defective server" on page 55
3.
"Locating the defective component" on page 58
7.2.4.3
Removing the defective 3.5-inch HDD module
Ê Remove the HDD/SSD module as described in section
inch HDD module" on page
7.2.4.4
Installing the new 3.5-inch HDD module
Ê Install the HDD/SSD module as described in section
HDD module" on page
166
164.
162.
Upgrade and Maintenance Manual
"Important information" on
"Removing the 3.5-
"Installing the 3.5-inch
RX100 S7