6.3.2.6

Connecting the power cord

Figure 49: Connecting the power cord
Ê Open the cable tie.
Ê Lay the power cord in the cable tie.
Ê Connect the power cord to the power supply module.
Ê Close the cable tie.
Ê Connect the power cord to the mains.
6.3.2.7

Checking the power supply modules

Ê Check whether the power supply modules work properly.
A power supply module works properly when the indicator (1) in
lights green. For more information see
page
447.
6.3.2.8

Concluding steps

Ê Perform the following procedures:
1. Only when replacing a power supply module in a non-redundant
configuration:
2.
"Performing a fan test after replacing a defective fan" on page 99
3.
"Closing the rack door" on page 73
RX100 S7
"Switching on the server" on page 72
Upgrade and Maintenance Manual
"Connectors and indicators" on
Power supply