7.2.3.4

Installing the 3.5-inch dummy module

Figure 80: Installing the 3.5-inch dummy module
Ê Push the dummy module into the empty bay until it engages.
7.2.3.5

Concluding steps

Ê Perform the following procedures:
1.
"Closing the rack door" on page 73
7.2.4

Replacing a 3.5-inch HDD module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD modules, see "PRIMERGY RX100 S7 Server -
Operating Manual".
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 1, 1E, 10, 5, 50, 6 or 60.
RX100 S7
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
165