6.3.2

Replacing a power supply module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Follow the safety instructions in chapter
page
43.
V
CAUTION!
When replacing a power supply module in a non-redundant
configuration, the server must be switched off first.
Replace the power supply module after specifying the one that
breaks down at work by revitalization.
I
Note for servers using CMA (Cable Management Arm)
Since the installed CMA is blocking power supply modules, additional
steps are required in order to remove or replace a power supply module:
Ê Unlock the CMA stopper.
Ê Remove the CMA stopper with the mounted crossbar.
Ê Support the CMA stopper, the crossbar and the CMA including cables
with your right hand.
Ê Remove the power supply module and carefully install a new power
supply module.
Ê Remount the complete assembly (CMA stopper, crossbar and CMA)
into the rail.