In order to permanently remove an operational HDD/SSD module that is part
of a RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array! Be sure to back up your data before deleting a RAID
array.
For more information, see the "ServerView Suite RAID Management"
user guide.
"Getting access to the component" on page 51
Ê
7.4.5.2
Removing a 2.5-inch HDD/SSD module
Ê Pinch the green locking clips and open the locking lever (see figure 61).
Ê Pull the HDD/SSD module out a few centimeters.
Ê Wait about 30 seconds to allow the HDD to spin down.
I
This is not necessary when removing an SSD.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê Pull the HDD/SSD module completely out of its bay.
TX1320 M4
Hard disk drives (HDD) and solid state drives (SSD)
Upgrade and Maintenance Manual
147