show power
Power drawn from the source: 0.0
Power available to the device: 0.0
Actual consumption
Measured at the port: 0.0
Maximum Power drawn by the device since powered on: 0.0
Absent Counter: 0
Over Current Counter: 0
Short Current Counter: 0
Invalid Signature Counter: 0
Power Denied Counter: 0
Interface: Gi3/6
Inline Power Mode: auto
Operational status: off
Device Detected: no
Device Type: n/a
IEEE Class: n/a
Discovery mechanism used/configured: Ieee and Cisco
Police: off
Power Allocated
Admin Value: 20.0
Power drawn from the source: 0.0
Power available to the device: 0.0
................
Related Commands
Command
power dc input
power inline
power inline consumption
power redundancy-mode
Catalyst 4500 Series Switch Cisco IOS Command Reference—Release IOS XE 3.4.0SG and IOS 15.1(2)SG)
2-898
Chapter 2
Cisco IOS Commands for the Catalyst 4500 Series Switches
Description
Configures the power DC input parameters on the switch.
Sets the inline-power state for the inline-power-capable
interfaces.
Sets the default power that is allocated to an interface for
all the inline-power-capable interfaces on the switch.
Configures the power settings for the chassis.
OL-27596 -01