When Installing in a Rack
This unit can be installed in a rack. When installing the unit in a rack,
to ensure efficient cooling, give attention to the following points.
• Ensure that the location provides good air flow and ventilation.
• Never block the cooling-fan intake port or ventilation port in
the front and rear panel.
• Avoid using the M-380 in sealed-type rack mounts. As this type
of rack does not permit heated air within the rack to be
expelled, the heated air is drawn into the M-380 as a result, thus
preventing adequately efficient cooling.
• If the rack's rear panel is not removable, ensure that a
ventilation port or exhaust fan is provided at the top of the
rack's rear panel to expel any accumulated heat.
• If the M-380 is mounted in a portable rack, remove both the
front and rear rack covers before use to ensure that the M-380's
front and rear panels remain unobstructed.
• When installing the unit on a rack, detach the rubber feet from
the bottom of the unit.
Use due caution when mounting the M-380 in a rack or other
enclosure so you don't get your fingers wedged or pinched.

AC power connections

Connect one end of the supplied AC power cord to a grounded AC
outlet, and the other end to the AC INPUT connector to provide
power for the M-380's internal power supply.
Use only the supplied power cords to prevent damage to the
units.
Attaching the power cord clamp
1.
Lower the power cord clamp to fasten the power cord.
fig.cord-cramp2.eps
Attaching the power cord hook
1.
As shown in the illustration, remove the two screws that
fasten the hook, and detach the power cord hook.
fig.cord-hook1.eps
2.
As shown in the illustration, fit the power cord hook over
the power cord, and fasten it using the two screws you
removed in step 1.
fig.cord-hook2.eps
Introduction
17