Lucent Technologies MERLIN LEGEND Release 7.0 System Planning Manual page 374

Hide thumbs Also See for MERLIN LEGEND Release 7.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 7.0
System Planning 555-670-112
G
NI-1 BRI Review
11.
Once you have determined your Service Configuration, do either of the
following:
For the Siemens SSD EWSD switch, each MLH group must be
assigned as either voice or data; alternate voice/data is not
supported since mixing the two types in one group could create call
interference. This constraint does not apply to the Lucent
Technologies 5ESS or the Northern Telecom DMS-100 switches.
The programming for Multiline Hunt is central office switch
dependent. The Lucent Technologies 5ESS and Siemens SSC
EWSD switches provide hunting through the Series Completion
feature. The Northern Telecom DMS-100 switch provides hunting
through the Multiline Hunt Group (MLHG) feature. Contact the local
service provider to determine what type of switching equipment is in
use and check the appropriate check box under the MLH
subheading of the Service Configurations section on page 2 of the
form.
The MERLIN LEGEND Communications System has currently been
tested with each switch type in the following configurations:
— Lucent Technologies 5ESS in a linear hunt group
— Northern Telecom DMS-100 in a circular hunt group
— Siemens SSC EWSD in a circular hunt group
Other configurations are possible, but are not guaranteed to work.
Appendix
H,
''NI-1 BRI
programming screens of the Series Completion and MLHG features.
These screens show the fields and parameters for the central office
switch and may be forwarded to the local service provider if
necessary.
If your Service Configuration will be IOC "S," check the check box
beside the IOC "S" selection under the Service Configuration
heading, then enter the number of BRI lines that will be provisioned
using this package.
If your Service Configuration will be MLH, check the check box
beside the MLH selection under the Service Configurations heading.
— Check the check box for MLHG (Northern Telecom DMS-100)
or Series Completion (Lucent Technologies 5ESS or
Siemens SSC EWSD).
— Enter the total number of BRI lines provisioned using MLH,
the number of BRI lines provisioned as voice only hunt
groups, the number of BRI lines provisioned as data only
hunt groups, and the number of BRI lines provisioned as
voice/data hunt groups in the spaces provided.
Provisioning," provides sample LEC