System Features
Extension and Remote Access FRL values must be equal to or greater
than the FRL value assigned to routes in order for users to access those
routes. A value of 0 is the most restrictive, and a value of 6 is the least
restrictive. The factory-set FRL value assigned to extensions is 3.
To restrict an extension from specific routes, assign an FRL value to the
extension that is lower than the route's value.
For example, if you want to limit a user from making calls on pools with
special-use lines/trunks such as WATS, assign a value of 0. If you want a
telephone used by a top executive to have unlimited use of any ARS route,
assign a value of 6.