  • Page 1 ® PARTNER Advanced Communications System Installation 518-456-162 Comcode 108355231 Issue 1 December 1998...
  • Page 2: Issue

    Lucent Technologies does not warrant that this product is immune from or will prevent unauthorized use of common-carrier telecommunication services or facilities accessed through or connected to it.
  • Page 3: Table Of Contents

    Installation Contents Overview A Sample System Setup Required Parts Installation Guidelines Telephones and Devices Combination Extensions Installation Procedures Wall-Mounting a Stand-Alone PARTNER ACS Processor Module Wall-Mounting a 2-Slot Carrier and Modules Wall-Mounting a 5-Slot Carrier and Modules Inserting Batteries in the PARTNER ACS Processor Module Initializing the System Connecting Lines and Extensions...
  • Page 4 Contents...
  • Page 5: Important Safety Instructions

    If any wiring from the extension jacks leaves the building premises, you must install Lucent Technologies IROB protectors (see “Requirements for Out-of Building Extensions”). CAUTION: Use only Lucent Technologies-manufactured PARTNER modules in the PARTNER Advanced Communications System. CAUTION: Environmental and electrical conditions must meet the requirements as listed in “Specifications”.
  • Page 6 Installation Installation...
  • Page 7: Overview

    To have a Lucent Technologies service technician install and customize your system or change existing wiring, call 800-247-7000 (in the continental U.S. only) or call your Lucent Technologies Representative or local Authorized Dealer. After installation, refer to the PARTNER Advanced Communications System Programming and Use guide for programming instructions.
  • Page 8 When someone presses the button on the doorphone, the designated extensions signal. (Any number of extensions can 9. MUSIC-ON-HOLD Jack. Lucent Technologies’ Magic on Hold be designated as doorphone alert extensions. For this example, is connected to this jack to provide customized music and extension 16 is the doorphone alert extension.)
  • Page 9 A Sample System Setup CONTROL UNIT PARTNER NE R 30 jun ct PA RT sur e Ad ct Clo Co nta PARTNER PARTNER Proc. MODULE R1.0 MODULE R1.0 MODULE R1.0 EXTENSIONS Extension 10 POWER RADIO PASS 555 1212 On/Off Redial Mute Feat/P Conf...
  • Page 10: Required Parts

    Installation Required Parts You may have multiple system component packages; Figure 2 shows the package contents. Check your packages to be sure you have the parts shown here (if not, call for support as instructed on the inside front cover of this guide). PARTNER Advanced Communications System Processor Module Remote Access AC Power Cord...
  • Page 11: Installation Guidelines

    PARTNER-model, MLS-model, MDC 9000, and TransTalk 9000-series system phones. System phones require at least 2-pair wiring and are ® compatible with Lucent Technologies 4-pair SYSTIMAX wiring. Call Assistant Intercom Autodialers with Busy Indication (PARTNER-CA48 for PARTNER-model phones or MLS-CA24 for MLS-model phones).
  • Page 12 Installation Industry-Standard Devices. Industry-standard devices (including standard phones) require 1-pair mounting cords; Lucent Technologies D2R mounting cords are recommended. — Standard Phones. Connect standard touch-tone or rotary dial phones to the system. You can connect a standard phone either alone or combined with a system phone.
  • Page 13 Call Reporting Devices. You can connect either a serial printer or a call accounting device, such as Lucent Technologies Call Accounting Terminal to the SMDR jack on the processor module to record and/or analyze call activity.
  • Page 14: Combination Extensions

    “Using a Direct Connection” which follows. If your phone does not have a built-in auxiliary jack or if you want to connect two standard devices together, you must use a Lucent Technologies 267F2 Bridging Adapter, see “Using a Bridging Adapter” which follows.
  • Page 15 Installation Guidelines Using a Bridging Adapter Figure 4 shows how to connect a system phone and a standard device or two standard devices using a Lucent Technologies 267F2 Bridging Adapter, which can be ordered separately. Lucent Technologies 267F2 Adapter Standard Device Only...
  • Page 16: Installation Procedures

    Installation Installation Procedures Before installing the system, be sure you read the safety instructions in the front of this guide. WARNING: There are no customer-serviceable components inside the system modules or carrier. There are hazardous voltages within that can cause severe or fatal personal injury.
  • Page 17 Installation Procedures a. Insert one of the #8 sheet metal screws into the screw hole at the top of the module. b. If you are not installing a second module, insert the other #8 sheet metal screw into the screw hole at the bottom of the module.
  • Page 18: Wall-Mounting A 2-Slot Carrier And Modules

    Installation Wall-Mounting a 2-Slot Carrier and Modules To wall-mount a 2-Slot Carrier, first follow the instructions in “Wall-Mounting a Stand-Alone PARTNER ACS Processor Module”. NOTE: To add a 308EC module to a PARTNER ACS processor module, the PARTNER ACS processor module must already be mounted on the wall. Before starting, disconnect the power cord from the power jack.
  • Page 19 Installation Procedures a. Slide the second module off the PARTNER ACS processor module and put it aside. b. Slide the 308EC module onto the PARTNER ACS processor module, making sure the mounting tracks interlock, as shown in the side view. a.
  • Page 20 Installation Insert the 3-1/2” #8 screw into the bottom of the modules. Tighten it until the mounting tracks of the PARTNER ACS processor module are flush against the wall with a 3/8” (1 cm.) gap between the wall and the rest of the PARTNER ACS processor module.
  • Page 21 If the lights are still out, in the continental U.S. call your local Authorized Dealer or the Lucent Technologies Technical Service Center at 800-628-2888. Outside the continental U.S., contact your Lucent Technologies Representative or local Authorized Dealer.
  • Page 22: Wall-Mounting A 5-Slot Carrier And Modules

    Installation Wall-Mounting a 5-Slot Carrier and Modules Install the 5-Slot Carrier within 5 feet (1.5 meters) of a properly grounded wall outlet (not controlled by a switch) and the network interface jacks. In addition, when you mount the carrier on the wall, leave at least 1 foot (0.3 meter) of clearance at the top and sides, and two feet (0.6 meter) at the front and bottom to ensure proper ventilation.
  • Page 23 Installation Procedures a. Verify that the PARTNER ACS processor module is in the center slot of the carrier. In the other slots, from left to right, first install the 308EC or 206 modules followed by the 400 or 200 modules. b.
  • Page 24 Installation a. Label the line and extension jacks. b. Connect line and telephone cords to the appropriate jacks on the new module. c. Route each cord through the MODULE hook on the front of its module. d. Connect the free end of each MODULE line cord to the appropriate network interface jack.
  • Page 25 If the lights are still out, in the continental U.S. call your local Authorized Dealer or the Lucent Technologies Technical Service Center at 800-628-2888. Outside the continental U.S., contact your Lucent Technologies Representative or local Authorized Dealer.
  • Page 26: Inserting Batteries In The Partner Acs Processor Module

    Installation Inserting Batteries in the PARTNER ACS Processor Module The PARTNER ACS processor module uses two user-replaceable, AAA-size standard alkaline batteries to guard against the loss of system programming in case of a power failure. These batteries will retain the system programming for 45 days to six months, depending on the freshness of the batteries.
  • Page 27 Installation Procedures Remove the battery assembly by gently pulling the tab at the bottom of the battery compartment cover. Insert two new AAA-size standard alkaline batteries into the metal battery clips by pushing them straight in, placing the negative (–) end of one battery into the bottom clip and the positive (+) end of the other battery into the top clip.
  • Page 28 Installation Pressing lightly on the battery icon on the front of the battery assembly, slide the locking latch downward to secure the assembly in place. The “plus” icon and the battery icon should now be visible on the front of the battery Unlocked assembly.
  • Page 29: Initializing The System

    Installation Procedures Initializing the System NOTE: The system must be powered down before you insert or remove a PC Card. The Backup/Restore, Automatic System Answer/Direct Extension Dial, PARTNER VOICE MESSAGING Basics, and software upgrade features of the system all require the use of a PC Card. If you plan to use any of these features, insert the appropriate PC Card in a PC Card Slot before applying power to the system.
  • Page 30 Installation Remove the PARTNER Remote Access PC Card. NOTE: For ACS Release 3.0., the PARTNER Remote Access PC Card is used to upgrade the system. This card is also used for remote PC administration and backup/restore and should not be removed or discarded. Re-power the system.
  • Page 31: Connecting Lines And Extensions

    Installation Procedures Check all green lights on the fronts of the modules. If all the Lights lights are lit, continue with “Connecting Lines and Extensions”. If any lights are out, do the following: a. If a single light is out, power down the control unit, reseat the module, then power up the control unit.
  • Page 32 Installation a. Connect line cords to the line jacks on the PARTNER ACS processor module and the 308EC, 206, and 400 modules. Start at the top with the line jacks on the PARTNER ACS processor module, and then move to the leftmost 308EC or 206 module.
  • Page 33 Installation Procedures a. Connect modular telephone cords to the extension jacks, starting at the top extension jack on the PARTNER ACS processor module. When that module is full, move to the leftmost 308EC or 206 module. Fill each module before moving on to the next module to the right.
  • Page 34: Assembling System Phones

    Installation Assembling System Phones All PARTNER-model system phones are shipped with a stand for either desk-mounting or wall-mounting the phone. Desk-Mounting Use the following procedure to desk-mount a phone: a. Gently place the phone upside down. b. Route the telephone cord through the hole in the top center of the stand.
  • Page 35 Installation Procedures a. While pressing in the tabs that protrude from the wide end of the stand, lower the stand to the phone. b. Release the tabs to lock the stand into one of the three positions provided by the openings in the back of the phone.
  • Page 36 For proper mounting, the wall plate must be a Lucent Technologies 630B connecting block. a. Plug one end of the telephone cord into the jack in the center of the wall plate.
  • Page 37 Installation Procedures NOTE: It is possible, with selected phone models, to wall-mount the phone in a manner that allows you to retain full functionality of the slide tray and tray card. Use one of the following procedures to accomplish this: If you have an 18/18D, 34D, or DSS phone, the tray can be removed from the “desk”...
  • Page 38: Connecting Contact Closure, Call Reporting (Smdr), Paging, And Music-On-Hold Devices

    (If you are connecting a standard phone and its mounting cord is loose, try a Lucent Technologies MODULE D2R mounting cord instead.) MODULE Ext.
  • Page 39 Installation Procedures Contact Closure Adjunct Use the following procedure to connect the Contact Closure: Insert the modular plug into the Contact Closure jack, the first jack on the PARTNER ACS processor module. Route the cord as you did for the line and extension cords, then connect the other end of the cord to the jack in the Contact Closure...
  • Page 40 You can purchase a Magic-On-Hold system from Lucent Technologies (800-446-5366), which includes the required license for the first year. This license...
  • Page 41: Connecting A Partner-Ca48

    Installation Procedures Insert an RCA phono plug into the Music-On-Hold jack on the PARTNER ACS processor module (located near the middle of the processor, below the line jacks). Route the cord as you did for line and extension cords, then connect the other end of the cord to the audio source.
  • Page 42 Installation a. Plug the blue-tinted connector (labeled D8AC) of the power cord into the jack on the power unit. CAUTION: Use only the power unit supplied with the PARTNER-CA48 Intercom Autodialer. b. Plug the other end (clear tinted) of the power cord into the J2 jack on the adapter.
  • Page 43: Equipment Upgrades

    Equipment Upgrades Equipment Upgrades Replacing System Modules The procedure for replacing a module depends on your configuration: If you have a... See... “Replacing a Stand-Alone PARTNER ACS Stand-alone PARTNER ACS Processor Module” processor module configuration 2-Slot carrier configuration “Replacing Modules in a 2-Slot Carrier” 5-Slot carrier configuration “Replacing Modules in a 5-Slot Carrier”...
  • Page 44 Installation Connect the line and extension cords one at a time, making sure to place the correct cords into their corresponding jacks on the new module. (See “Connecting Lines and Extensions” earlier in this guide.) Reconnect the power cord. CAUTION: The power cord should hang straight down from the connector, flush against the plastic case for the entire length of the board.
  • Page 45 Equipment Upgrades Replacing Modules in a 2-Slot Carrier WARNING: Before starting, verify that you have batteries installed in the PARTNER ACS processor module, and then disconnect the power cord from the power jack on the carrier. For an illustration showing the location of the power jack, see “Initializing the System”...
  • Page 46 Installation Pull the carrier to the right to remove it. a. Slide the top module to the left to disengage its interlocking mounting tracks from the PARTNER ACS processor module. b. If you are replacing the PARTNER ACS processor module, skip to Step 7. If you are replacing the top module, continue with Step 6.
  • Page 47 Equipment Upgrades a. Remove the screw at the top of the PARTNER ACS processor module and remove the module from the wall. b. Mount the new PARTNER ACS processor module by following the instructions in “Wall-Mounting a Stand-Alone PARTNER ACS Processor Module”...
  • Page 48 Installation Replacing Modules in a 5-Slot Carrier WARNING: Before starting, move the On/Off switch to “off” and unplug the power cord. Verify that you have batteries installed in the PARTNER ACS processor module, and then disconnect the power cord from the wall jack on the carrier. a.
  • Page 49 Equipment Upgrades c. If you are replacing a module with one of a different type, make sure that all 400 (or 200) modules are installed to the right of all 308EC or 206 modules, and that the PARTNER ACS processor module remains in the center slot.
  • Page 50: Adding New Modules

    Installation Check that all green lights on the Lights fronts of the modules are lit: a. If a single light is out , power down the control unit, reseat the module, then power up the control unit. b. If multiple lights are out , power down the control unit, reseat the leftmost module that has a light out, then power up the control unit.
  • Page 51 Equipment Upgrades a. Move the On/Off switch to the “Off” position (“O”). b. Loosen the screw on the lower front of the carrier’s cover. Then place one hand on the handle on the lower front and the other hand on the top of the cover.
  • Page 52 Installation a. See “Connecting Lines and Extensions” for instructions for connecting line and/or extension jack cords to the new module. b. Reconnect the power cord. CAUTION: The power cord should hang straight down from the connector, flush against the plastic case for the entire length of the board. Do not install the power cord at an angle to the case or with a loop in it.
  • Page 53 Equipment Upgrades Inserting or Removing a PC Card CAUTION: Before starting, verify that you have batteries installed in the PARTNER ACS processor module. If you have an existing 5-Slot Carrier, move the carrier’s On/Off switch to the “Off” position (“O”). For all types of installations, disconnect the power cord from the power jack.
  • Page 54 Installation Check that all green lights on the fronts of the modules are lit: Lights a. If a single light is out, power down the control unit, reseat the module, then power up the control unit. b. If multiple lights are out, power down the control unit, reseat the leftmost module that has a light out, then power up the...
  • Page 55: Capacities

    Specifications Capacities System Module Extension Jack 19 outside lines via line jacks on ACS Processor Module: Maximum two devices per one ACS processor module plus extension jack, total REN on 3 outside lines four 400 modules jack not to exceed 2.0 [System 8 extensions 40 extensions via extension phone REN is 0.0(zero)]...
  • Page 56: Dimensions And Weights (Approx.)

    Specifications Dimensions and Weights (approx.) Processor Module 11"(D) x 17" (H) x 1.5" (W) or 27.9 x 4.5 lbs or 2 kgs 43.2 x 3.8 cm 200 module 11"(D) x 17" (H) x 1.5" (W) or 27.9 x 4.5 lbs or 2 kgs 43.2 x 3.8 cm 206 module 11"(D) x 17"...
  • Page 57: Specifications Description

    Specifications Description Switch Fabric Full digital, nonblocking Electrical 35 Watts (120 BTUs/hr.) per ACS processor module during normal power Specifications consumption 45 Watts (154 BTUs/hr.) per ACS processor module during maximum power consumption 10 Watts (35 BTUs/hr.) per 400 module, normal and maximum power consumption 25 Watts (90 BTUs/hr.) per 206 module during normal power consumption 35 Watts (120 BTUs/hr.) per 206 module during maximum power consumption 30 Watts (105 BTUs/hr.) per 308EC module during normal power consumption...
  • Page 58 Specifications Specifications Description Music-on-Hold Jack Accepts 2 Volts at 50 Kohms maximum input Specifications 0 - 18 dB attenuation CONTACT Operates up to 150 feet (45.72 meters) from control unit using 24 gauge solid CLOSURE Adjunct conductor wire if 2 Contact Closures used; up to 800 feet (243.84 meters) from Jack Specifications control unit using 24 gauge solid conductor wire if only 1 Contact Closure used Install the Contact Closure Adjunct in the same building as the control unit;...
  • Page 59 Building Installations control unit and device from electrical surges: — System phone: two Lucent Technologies IROB protectors — Standard phone: two Lucent Technologies IROB protector plus one carbon block protector Installation of a Contact Closure Adjunct controlled device outside the building...
  • Page 60 Specifications Specifications Description Government U.S.: Approvals and Local FCC Part 68 Key System registration: FCC #AS5USA-61630-K-F-E Phone Company FCC Part 68 Pooling and Hybrid System registration: FCC #A55USA-21213-MF3 Information — Class A: 5-Slot Configuration 2-Slot Configuration with 308EC or PARTNER MAIL VS —...