Lucent Technologies MERLIN LEGEND Release 7.0 System Planning Manual page 366

Hide thumbs Also See for MERLIN LEGEND Release 7.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 7.0
System Planning 555-670-112
F
Unit Load Calculation
Unit Load Worksheet
Module
008 (ATL)
008 MLX
016 MLX
008 OPT
012 (T/R)
016 ETR
016 (T/R)
100D
400 (LS)
400 EM
400 GS/LS/TTR
408 (LS-ATL)
408 GS/LS
408 GS/LS-MLX
408 GS/LS-ID-MLX
412 LS-ID-ETR
800 (LS)
800 GS/LS
800 GS/LS-ID
800 DID
800 NI-BRI
MERLIN LEGEND
Mail
Total Estimated Unit Load:
If the total is less than 96 (for the 391C1 power supply), 72 (for the 391A3
power supply), or 48 (for the 391A1 or 391A2 power supplies), no further
calculation is required.
If the total is 96 (391C1 power supply), 72 (391A3 power supply), or 48
(391A1 or 391A2 power supplies) or more, continue to Step 6.
Qty
x
Unit Load
12.0
13.25
13.25
8.0
8.4
24
12.8
0.0
0.0
8.0
0.0
12.0
12.0
13.5
13.5
18
0.0
0.0
0.0
8.0
0.0
0.0
Issue 1
April 1999
= Total
F-4