Configuring A Zone For A Virtual Device - HP Cisco MDS 9020 - Fabric Switch Configuration Manual

Cisco mds 9000 family cli configuration guide, release 3.x (ol-16184-01, april 2008)
Hide thumbs Also See for Cisco MDS 9020 - Fabric Switch:
Table of Contents

Advertisement

Configuring SDV
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Configuring a Zone for a Virtual Device

After configuring a virtual device, you must create a zone that includes all the other real devices and the
virtual device as members, and add this zone to a zone set, which you can activate. You can add the
virtual device to the zone using the configured name and member type as the device alias.
Note
This configuration process does not support interoperability. If you are working in interop-VSANs, we
recommend that you configure the zone directly using the system-assigned pWWN of the virtual device.
Figure 20-6
primary device is online.
Figure 20-6
To add the virtual device to a zone as a zone member, follow these steps:
Step 1
switch# config t
Step 2
switch(config)# zoneset name zs1 vsan 1
Step 3
switch(config-zoneset)# zone name zone1
Step 4
switch(config-zoneset-zone)# member
device-alias vdev1
or
switch (config-zoneset-zone)# member pwwn
50:00:53:00:01:fa:70:09
Step 5
switch(config-zoneset-zone)# member pwwn
21:22:5:d8:15:11:8:8
Step 6
switch(config-zoneset-zone)# end
Cisco MDS 9000 Family CLI Configuration Guide
20-6
shows a virtual device-name device alias (vt1) zoned with the real devices activated; the
Zoning the Virtual Device with Real Devices
SAN Device Virtualization Zone
SAN Device
i1pwwn
Virtualization
vtpwwn
vt1
t1pwwn
i2pwwn
i3pwwn
i1
i2
i3
Virtual
Device
t2pwwn
t1
t2
Primary
Secondary
Enters configuration mode.
Groups zones under one zone set named zs1 in the
VSAN, vsan 1. Enters zone set submode.
Creates the zone zone1.
Adds a virtual device (vdev1) as device-alias type
zone member to the zone.
Alternatively, adds a virtual device as pWWN type
zone member to the zone.
Adds the real device to the zone.
Exits all modes.
Chapter 20
SAN Device Virtualization
OL-16184-01, Cisco MDS SAN-OS Release 3.x