Displaying Module Temperature - HP Cisco MDS 9020 - Fabric Switch Configuration Manual

Cisco mds 9000 family cli configuration guide, release 3.x (ol-16184-01, april 2008)
Hide thumbs Also See for Cisco MDS 9020 - Fabric Switch:
Table of Contents

Advertisement

About Module Temperature
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
A threshold value of -127 indicates that no thresholds are configured or applicable.
Note
Tip

Displaying Module Temperature

Use the show environment temperature command to display temperature sensors for each module (see
Example 10-4
Example 10-4 Displays Temperature Information for Generation 1 Hardware
switch# show environment temperature
---------------------------------------------------------------
Module
---------------------------------------------------------------
2
2
5
5
6
6
Cisco MDS 9000 Family CLI Configuration Guide
10-16
Minor threshold—When a minor threshold is exceeded, a minor alarm occurs and the following
action is taken for all four sensors:
System messages are displayed.
Call Home alerts are sent (if configured).
SNMP notifications are sent (if configured).
Major threshold—When a major threshold is exceeded, a major alarm occurs and the following
action is taken.
For sensors 1, 3, and 4 (outlet and onboard sensors):
System messages are displayed.
Call Home alerts are sent (if configured).
SNMP notifications are sent (if configured).
For sensor 2 (intake sensor):
If the threshold is exceeded in a switching module, only that module is shut down.
If the threshold is exceeded in an active supervisor module with HA-standby or standby present,
only that supervisor module is shut down and the standby supervisor module takes over.
If you do not have a standby supervisor module in your switch, you have an interval of 2 minutes
to decrease the temperature. During this interval the software monitors the temperature every
five (5) seconds and continuously sends system messages as configured.
To realize the benefits of these built-in, automatic sensors on any switch in the Cisco MDS 9500
Series, we highly recommend that you install dual supervisor modules. If you are using a Cisco
MDS 9000 Family switch without dual supervisor modules, we recommend that you
immediately replace the fan module if even one fan is not working.
and
Example
10-5).
Sensor
MajorThresh
(Celsius)
Outlet
75
Intake
65
Outlet
75
Intake
65
Outlet
75
Intake
65
MinorThres
CurTemp
(Celsius)
(Celsius)
60
35
50
33
60
44
50
36
60
42
50
35
Chapter 10
Managing System Hardware
Status
ok
ok
ok
ok
ok
ok
OL-16184-01, Cisco MDS SAN-OS Release 3.x

Advertisement

Table of Contents
loading