About Fan Modules
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Example 10-6 Displays Chassis Fan Information
switch# show environment fan
------------------------------------------------------
Fan
------------------------------------------------------
Chassis
PS-1
PS-2
The possible Status field values for a fan module on the Cisco MDS 9500 Series switches are as follows:
If the fan module is operating properly, the status is ok.
If the fan is physically absent, the status is absent.
If the fan is physically present but not working properly, the status is failure.
On the Cisco MDS 9513 Director, the front fan module has 15 fans. If the front fan module
(DS-13SLT-FAN-F) State field contains "failure" in the show environment fan command output, it also
displays the numbers of the failing fans (see
Example 10-7 Displays Cisco MDS 9513 Front Fan Module Failure
switch# show environment fan
------------------------------------------------------
Fan
------------------------------------------------------
Chassis
Chassis
PS-1
PS-2
Figure 10-1
Cisco MDS 9000 Family CLI Configuration Guide
10-18
Model
DS-9SLOT-FAN
--
--
Model
DS-13SLT-FAN-F
DS-13SLT-FAN-R
--
--
shows the numbering of the fans in the front fan module on the Cisco MDS 9513 Director.
Chapter 10
Hw
Status
1.2
ok
--
ok
--
absent
Example
10-7).
Hw
Status
0.3
failure 3 5 6 13
0.3
ok
--
ok
--
ok
OL-16184-01, Cisco MDS SAN-OS Release 3.x