Chapter 7
Software Images
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
This supervisor (sup-2)
-----------------------
Redundancy state:
Supervisor state:
Other supervisor (sup-1)
------------------------
Redundancy state:
Supervisor state:
Enable the management interface.
Step 12
switch# config t
switch(config)# interface mgmt 0
switch(config-if)# no shutdown
switch(config-if)# end
switch#
Copy the running configuration to the startup configuration on the active Supervisor-1 module to ensure
Step 13
that any running configuration changes are saved to the startup configuration and that the ASCII
configuration is synhronized and current on the warm standby Supervisor-2 module.
switch# copy running-config start-config
If your switch has SSMs installed and intelligent services are configured, perform
Step 14
Otherwise, continue to
a.
Power down all SSMs on the switch.
switch# config t
switch(config)# poweroff module 2
switch(config)# exit
switch#
Caution
Verify that the SSMs are powered down.
b.
switch# show module
Mod
---
1
2
3
4
5
6
...
c.
Copy the contents of the SSM NVRAM to the standby Supervisor-2 module.
switch# copy ssm-nvram standby-sup
Step 15
Load the system image from bootflash on the Supervisor-2 module.
switch(boot)# load bootflash:system-image
Uncompressing system image: bootflash:/iisan-3-3-0-74
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCC
OL-16184-01, Cisco MDS SAN-OS Release 3.x
Active
Active
Internal state:
Active with warm standby
Standby
Warm standby
Internal state:
Warm standby
Step
16.
Do not copy the running configuration to the startup configuration after powering down the
SSMs. If you do, you will lose the configuration on the SSM interfaces.
Ports
Module-Type
-----
-------------------------------- ------------------ ------------
16
1/2 Gbps FC Module
32
Storage Services Module
8
IP Storage Services Module
12
1/2/4 Gbps FC Module
0
Supervisor/Fabric-2
0
Supervisor/Fabric-1
Maintaining Supervisor Modules
Model
Status
DS-X9016
ok
powered-dn
DS-X9308-SMIP
ok
DS-X9112
ok
DS-X9530-SF2-K9
ha-standby
DS-X9530-SF1-K9
active *