Command Line Interface Reference for the ProSafe 7200RS Series Layer-2 Stackable Switches
10.1.19.1 no snmp trap link-status all
This command disables link status traps for all interfaces.
Note: This command is valid only when the Link Up/Down Flag is enabled. See
Format
Mode
10.2 SNMP Show Commands
This section describes the commands you use to view SNMP status and configuration
information.
10.2.1 show snmpcommunity
This command displays SNMP community information. Six communities are supported.
You can add, change, or delete communities. The switch does not have to be reset for
changes to take effect.
The SNMP agent of the switch complies with SNMP Versions 1, 2 or 3. For more
information about the SNMP specification, see the SNMP RFCs. The SNMP agent sends
traps through TCP/IP to an external SNMP manager based on the SNMP configuration
(the trap receiver and other SNMP community parameters).
Format
Mode
SNMP Community
Name
Client IP Address
10-10
Section 10.1.11 "snmp-server traps linkmode" on page 6
no snmp trap link-status all
Global Config
show snmpcommunity
Privileged EXEC
The community string to which this entry grants access. A
valid entry is a case-sensitive alphanumeric string of up to 16
characters. Each row of this table must contain a unique com-
munity name.
An IP address (or portion thereof) from which this device
will accept SNMP packets with the associated community.
The requesting entity's IP address is ANDed with the Subnet
Mask before being compared to the IP Address. Note: If the
v1.0, October 2008
SNMP Commands