Omron SYSMAC CJ - REFERENCE MANUAL 08-2008 Reference Manual page 403

Programmable controllers
Hide thumbs Also See for SYSMAC CJ - REFERENCE MANUAL 08-2008:
Table of Contents

Advertisement

Data Shift Instructions
Ladder Symbol
Variations
Applicable Program Areas
Operands
Operand Specifications
SFTR(084)
C
St
E
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
Block program areas
OK
C: Control Word
15 14 13 12
Note St and E must be in the same data area.
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
C: Control word
St: Starting word
E: End word
Step program areas
OK
OK
Shift direction
1 (ON): Left
0 (OFF): Right
Data input
Shift input
Reset
C
CIO 0000 to CIO 6143
W000 to W511
H000 to H511
A000 to A959
A448 to A959
T0000 to T4095
C0000 to C4095
D00000 to D32767
E00000 to E32767
En_00000 to En_32767
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
---
DR0 to DR15
---
Section 3-9
SFTR(084)
@SFTR(084)
Not supported
Subroutines
Interrupt tasks
OK
St
E
363

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cs seriesSysmac one nsj seriesSysmac cj series

Table of Contents