Double-precision Floating-point Instructions (CS1-H, CJ1-H, CJ1M, or CS1D Only)
Description
Note
670
Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
Index Registers
Indirect addressing
using Index Registers
/D(848) divides the double-precision (64-bit) floating-point number in words
Dd to Dd+3 by the double-precision (64-bit) floating-point number in words Dr
to Dr+3 and places the result in words D to D+3. (The floating point data must
be in IEEE754 format.)
S1+3
S1+2
S2+3
S2+2
D+3
D+2
If the absolute value of the result is greater than the maximum value that can
be expressed as floating-point data, the Overflow Flag will turn ON and the
result will be output as
If the absolute value of the result is less than the minimum value that can be
expressed as floating-point data, the Underflow Flag will turn ON and the
result will be output as 0.
The various combinations of dividend and divisor data will produce the results
shown in the following table.
Divisor
0
0
See note 3.
Numeral
0
+
0
0
NaN
1. The results could be zero (including underflows), a numeral, + , or – .
2. The results will be zero for underflows.
3. The Error Flag will be turned ON and the instruction will not be executed.
Dd
E00000 to E32764
En_00000 to En_32764
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
---
---
---
,IR0 to ,IR15
–2048 to +2047 ,IR0 to –2048 to +2047 ,IR15
DR0 to DR15, IR0 to IR15
,IR0+(++) to ,IR15+(++)
,–(– –)IR0 to, –(– –)IR15
S1+1
S1
Dividend (floating-point data, 64-bits)
S2+1
S2
Divisor (floating-point data, 64-bits)
D+1
DCH
Result (floating-point data, 64-bits)
.
Dividend
Numeral
+
+/–
+
See note 1.
+/–
See note 2.
See note 3. See note 3.
See note 2.
See note 3. See note 3.
Section 3-16
Dr
D
NaN
+/–
See note 3.