Conversion Instructions

3-12-14 SIGNED BCD TO BINARY: BINS(470)

Purpose
Ladder Symbol
Variations
Applicable Program Areas
Operands
Operand Specifications
Converts one word of signed BCD data to one word of signed binary data.
BINS(470)
C
S
D
Variations
Executed Each Cycle for ON Condition
Executed Once for Upward Differentiation
Executed Once for Downward Differentiation Not supported
Immediate Refreshing Specification
Block program areas
OK
OK
C: Control Word
Specifies the signed BCD format. C must be 0000 to 0003.
Area
CIO Area
Work Area
Holding Bit Area
Auxiliary Bit Area
Timer Area
Counter Area
DM Area
EM Area without bank
EM Area with bank
Indirect DM/EM
addresses in binary
Indirect DM/EM
addresses in BCD
Constants
Data Registers
C: Control word
S: Source word
D: Destination word
Step program areas
Subroutines
OK
C
CIO 0000 to CIO 6143
W000 to W511
H000 to H511
A000 to A959
T0000 to T4095
C0000 to C4095
D00000 to D32767
E00000 to E32767
En_00000 to En_32767
(n = 0 to C)
@ D00000 to @ D32767
@ E00000 to @ E32767
@ En_00000 to @ En_32767
(n = 0 to C)
*D00000 to *D32767
*E00000 to *E32767
*En_00000 to *En_32767
(n = 0 to C)
#0000 to #0003
---
(binary)
DR0 to DR15
Section 3-12
BINS(470)
@BINS(470)
Not supported
Interrupt tasks
OK
S
D
A448 to A959
517