7.6.2.5 Alarm Output
After alarm output is triggered by a motion detection alarm, Boolean alarm, the camera can output
alarm information to the third-party device if alarm output is set correctly to Normally Open or Normally
Closed. The alarm output duration is configurable.
NOTE!
This function is not supported by some models. Please see the actual model for details.
Click Setup>Events>Common Alarm >Alarm Output.
1.
Select the alarm and set the alarm name.
2.
Set the status to N.O. (default setting) and set the alarm duration.
3.
Set relay mode to better adapt to third-party alarm devices like alarm lights. Please select
the trigger mode according to your third-party alarm device.
Item
Monostable The alarm output triggers the third-party alarm device by pulse.
Bistable
The alarm output triggers the third-party alarm device by high or low level.
4.
Set actions to be triggered by an input alarm and the plan. For the detailed steps, see the
descriptions of alarm-triggered actions in 7.6.2 Configuring Motion Detection Alarm.
UNI IP Series Network Cameras – H265, 2MP / 5MP