Ricoh MP C307 Field Service Manual page 794

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

3-627-
ID Pattern Extraction: Set
021
3-627-
ID Pattern Extraction: Set
022
3-627-
ID Pattern Extraction: Set
031
3-627-
ID Pattern Extraction: Set
041
3-628-
ID Pattern Timing: Set
001
3-628-
ID Pattern Timing: Set
002
3-628-
ID Pattern Timing: Set
003
3-628-
ID Pattern Timing: Set
004
3-628-
ID Pattern Timing: Set
005
3-630-
Dev gamma: Disp/Set
001
3-630-
Dev gamma: Disp/Set
002
3-630-
Dev gamma: Disp/Set
003
3-630-
Dev gamma: Disp/Set
004
3-630-
Dev gamma: Disp/Set
011
3-630-
Dev gamma: Disp/Set
012
3-630-
Dev gamma: Disp/Set
013
3-630-
Dev gamma: Disp/Set
014
3-630-
Dev gamma: Disp/Set
061
Edge Lower Limit
Edge Lower Limit: Std
Speed 2
Vsg Upper Threshold
Vsg Lower Threshold
Scan: YMCK
Detection Delay Time
Delay Time
MUSIC Delay Time
Delay Time: Std Speed 2
Current:Bk
Current:C
Current:M
Current:Y
Target:Bk
Target:C
Target:M
Target:Y
Toner Density: Bk
3.SP Mode Tables
ENG*
[ 0 to 255 / * / 1point ]
*MP C307: 14
*MP C407: 12
ENG*
[ 0 to 255 / 10 / 1point ]
ENG*
[ 0 to 5 / 4.8 / 0.001V ]
ENG*
[ 0 to 5 / 3 / 0.001V ]
ENG*
[ -500 to 500 / 0 / 0.1mm ]
ENG*
[ 0 to 2500 / 0 / 1msec ]
ENG*
[ 0 to 2500 / * / 1msec ]
*MP C307: 701
*MP C407: 641
ENG*
[ -2500 to 2500 / 150 /
1msec ]
ENG*
[ 0 to 2500 / 592 / 1msec ]
ENG*
[ 0.1 to 6 / 0.9 /
0.01mg/cm2/-kV ]
ENG*
[ 0.1 to 6 / 0.9 /
0.01mg/cm2/-kV ]
ENG*
[ 0.1 to 6 / 0.9 /
0.01mg/cm2/-kV ]
ENG*
[ 0.1 to 6 / 0.9 /
0.01mg/cm2/-kV ]
ENG*
[ 0.5 to 2.55 / 0.9 /
0.01mg/cm2/-kV ]
ENG*
[ 0.5 to 2.55 / 0.9 /
0.01mg/cm2/-kV ]
ENG*
[ 0.5 to 2.55 / 0.9 /
0.01mg/cm2/-kV ]
ENG*
[ 0.5 to 2.55 / 0.9 /
0.01mg/cm2/-kV ]
ENG*
[ 0 to 25.5 / 0 / 0.1wt% ]