Code
task is full.
4-01
Line current was cut
4-10
Communication failed because of an ID
Code mismatch (Closed Network) or Tel.
No./CSI mismatch (Protection against
Wrong Connections)
5-00
Data reconstruction not possible
5-10
DCR timer expired
5-20
Storage impossible because of a lack of
memory
5-21
Memory overflow
5-23
Print data error when printing a substitute
rx or confidential rx message
5-25
SAF file access error
6-00
G3 ECM - T1 time out during reception
of facsimile data
6-01
G3 ECM - no V.21 signal was received
6-02
G3 ECM - EOR was received
6-04
G3 ECM - RTC not detected
6-05
G3 ECM - facsimile data frame not
received within 18 s of CFR, but there
was no line fail
6-06
G3 ECM - coding/decoding error
6-08
G3 ECM - PIP/PIN received in reply to
PPS.NULL
6-09
G3 ECM - ERR received
Meaning
Suggested Cause/Action
Check the line connector.
Check for line problems.
Replace the FCU.
Get the ID Codes the same and/or the CSIs
programmed correctly, then resend.
The machine at the other end may be defective.
Replace the FCU
Replace the FCU.
Temporary memory shortage.
Test the SAF memory.
Test the SAF memory.
Ask the other end to resend the message.
Replace an SD card or HDD.
Replace the FCU.
Try adjusting the rx cable equalizer.
Replace the FCU.
Check the line connection.
Check for a bad line or defective remote terminal.
Replace the FCU.
Check the line connection.
Check for a bad line or defective remote terminal.
Replace the FCU.
Try adjusting the rx cable equalizer
Cross reference
Rx cable equalizer - G3 Switch 07 (PSTN)
Defective FCU.
The other terminal may be defective.
The other end pressed Stop during communication.
The other terminal may be defective.
Check for a noisy line.
Adjust the tx levels of the communicating machines.
See code 6-05.
3.Troubleshooting
29