Ricoh MP C307 Field Service Manual page 1109

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

Code
after sending CI.
0-75
The called terminal fell back to T.30
mode, because it could not detect a CM
in response to ANSam (ANSam timeout).
0-76
The calling terminal fell back to T.30
mode, because it could not detect a JM in
response to CM
(CM timeout).
0-77
The called terminal fell back to T.30
mode, because it could not detect a CJ in
response to JM
(JM timeout).
0-79
The called terminal detected CI while
waiting for a V.21 signal.
0-80
The line was disconnected due to a
timeout in V.34 phase 2 – line probing.
0-81
The line was disconnected due to a
timeout in V.34 phase 3 – equalizer
training.
0-82
The line was disconnected due to a
timeout in the V.34 phase 4 – control
channel start-up.
0-83
The line was disconnected due to a
timeout in the V.34 control channel
restart sequence.
0-84
The line was disconnected due to
abnormal signaling in V.34 phase 4 –
control channel start-up.
0-85
The line was disconnected due to
abnormal signaling in V.34 control
Meaning
Suggested Cause/Action
ANSam was too short to detect.
Check the line connection and condition.
Try making a call to another V.8/V.34 fax.
The terminal could not detect ANSam.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.
The called terminal could not detect a CM due to
noise, etc.
Check the line connection and condition.
Try making a call to another V.8/V.34 fax.
The calling terminal could not detect a JM due to
noise, etc.
A network that has narrow bandwidth cannot pass JM
to the other end.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.
Check for line noise or other line problems.
If this error occurs, the called terminal falls back to
T.30 mode.
The guard timer expired while starting these phases.
Serious noise, narrow bandwidth, or low signal level
can cause these errors.
If these errors happen at the transmitting terminal:
Try making a call at a later time.
Try using V.17 or a slower modem using dedicated tx
parameters.
Try increasing the tx level.
Try adjusting the tx cable equalizer setting.
If these errors happen at the receiving terminal:
Try adjusting the rx cable equalizer setting.
Try increasing the tx level.
Try using V.17 or a slower modem if the same error is
frequent when receiving from multiple senders.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
3.Troubleshooting