Ricoh MP C307 Field Service Manual page 1181

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

NCU Parameters
The following tables give the RAM addresses and the parameter calculation units that the machine uses for
ringing signal detection and automatic dialing. The factory settings for each country are also given. Most of these
must be changed by RAM read/write (SP2-102), but some can be changed using NCU Parameter programming
(SP2-103, 104 and 105); if SP2-103, 104 and 105 can be used, this will be indicated in the Remarks column. The
RAM is programmed in hex code unless (BCD) is included in the Unit column.
The following addresses describe settings for the standard NCU.
#
RAM
Addr.
CC 680500
Country/Area code for
NCU parameters
Country Code List
Country/Area
France
Germany
UK
Italy
Austria
Belgium
Denmark
Finland
Ireland
Norway
Sweden
Switzerland
#
RAM
Function
Addr.
01 6805B4
PSTN: Tx level from the modem
02 680572
Acceptable ringing signal frequency:
range 1, upper limit
03 680573
Acceptable ringing signal frequency:
range 1, lower limit
04 680574
Acceptable ringing signal frequency:
Function
Use the Hex value to program the country/area code directly into
this address, or use the decimal value to program it using SP2-
103-001
Decimal
Hex
00
00
01
01
02
02
03
03
04
04
05
05
06
06
07
07
08
08
09
09
10
0A
11
0B
Remarks
Country/Area
Asia
Japan
Hong Kong
South Africa
Australia
New Zealand
Singapore
Malaysia
China
Taiwan
Korea
Brazil
Unit
Remarks
-N – 3
SP2-103-002
dBm
1000/ N
SP2-103-003
(Hz).
SP2-103-004
SP2-103-005
4.Service Tables
Decimal
Hex
18
12
19
13
20
14
21
15
22
16
26
17
24
18
25
19
26
1A
27
1B
28
1C
29
1D
99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mp c407D296D297D298D299

Table of Contents