Ricoh MP C307 Field Service Manual page 1164

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

4.Service Tables
0: OFF
1: ON
6
Not used
7
Action when there is no box with an
F-code that matches the received
SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Communication Switch 18 (SP No. 1-104-025)
No
Function
0-4
Not used
5
IP-Fax dial-in routing selection
0: Off
1: On
6-7
Not used
Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B (SP No. 1-104-028)
No
Function
0-
Extension access code (0
7
to 7) to turn V.8 protocol
On/Off
0: On
1: Off
Communication Switch 1C (SP No. 1-104-029)
No
Function
0-
Extension access code (8
1
and 9) to turn V.8 protocol
On/Off
0: On
1: Off
2-
Not used
7
82
dial-in line and transfers received data from each PSTN dial-in
number to each address.
Do not change the settings.
Change this setting when the customer requires.
Comments
Do not change the settings.
1: Transfers received data to each IP-Fax dial-in number.
IP-Fax dial-in number is a 4-digit number.
Do not change the settings.
Comments
If the PABX does not support V.8/V.34 protocol procedure, set this bit to "1"
to disable V.8.
Example: If "0" is the PSTN access code, set bit 0 to 1. When the machine
detects "0" as the first dialed number, it automatically disables V.8 protocol.
(Alternatively, if "3" is the PSTN access code, set bit 3 to 1.)
Comments
Refer to communication switch 1B.
Example: If "8" is the PSTN access code, set bit 0 to 1. When the machine
detects "8" as the first dialed number, it automatically disables V.8 protocol.
(If "9" is the PSTN access code, use bit 1.)
Do not change the settings.