4.Service Tables
3
Hang up setting at DIS reception disabled
0: No hang up
1: Hang up after transmitting DCN
4
Number of times for training
0: 1 time, 1: 2 times
5
Space CSI transmission setting at no CSI
registration
0: Not transmitted
1: Transmitted
6-7
Not used
IP Fax Switch 08 (SP No. 1-111-009)
No. Function
0-1
T1 timer adjustment
Bit 1
Bit 0
0
0
0
1
1
0
1
1
2-3
T4 timer adjustment
Bit 3
Bit 2
0
0
0
1
1
0
1
1
4-5
T0 timer adjustment
Bit 5
Bit 4
0
0
0
1
1
0
1
1
6-7
Not used
IP Fax Switch 09 (SP No. 1-111-010)
96
Comments
Adjusts the T1 timer.
The default is "00" (35 seconds).
35 s
40 s
50 s
60 s
Adjust the T4 timer.
The default is "00" (3 seconds).
3 s
3.5
s
4 s
5 s
Adjusts the fail safe timer. This timer sets the interval between "setup" data
transmission and T.38 phase decision. If your destination return is late on the
network or G3 fax return is late, adjust the longer interval timer.
75 s
The default is "00" (75 seconds).
120
s
180
s
240
s
Do not change these settings.
Sets whether the machine disconnects after DIS
reception.
Selects the number of times training is done at the same
bit rate.
When "0" is selected, frame data is enabled.
When "1" is selected, the transmitted data is all spaces.
Do not change these settings.