3.SP Mode Tables
002
1-951-
Fan Start Time Set
003
1-951-
Fan Start Time Set
004
1-952-
Fan Control Off Mode
001
Time Set
1-953-
Extra Fan Control
001
1-953-
Extra Fan Control
006
1-953-
Extra Fan Control
007
1-953-
Extra Fan Control
008
1-955-
Fan Control
001
1-955-
Fan Control
002
1-955-
Fan Control
004
1-955-
Fan Control
005
1-955-
Fan Control
006
1-955-
Fan Control
007
46
PSU Fan
Laser Unit Fan
Operation Status
Extra Fan Start Temp.
Extra Fan Stop Temp. Threshold
Set: Extra Operation ON/OFF
PCDU Fan Operation Sw Temp.
Fusing Fan Operation Sw Temp.
Laser Unit Fan Operation Sw Temp.
Fan Operation Sw Temp. Threshold
PSU Fan Operation Start Time2
PSU Fan Ctrl Off Mode Time2
ENG*
[ 0 to 120 / 0 / 1sec ]
ENG*
[ 0 to 120 / 0 / 1sec ]
ENG*
[ 10 to 60 / 10 / 1min ]
ENG*
[ 0 or 1 / 0 / 1 ]
ENG*
[ 0 to 50 / 5 / 0.1deg ]
ENG*
[ 0 to 50 / 2 / 0.1deg ]
ENG*
[ 0 or 1 / 1 / 1 ]
ENG*
[ 0 to 100 / 38 /
0.1deg ]
ENG*
[ 0 to 100 / 0 / 0.1deg ]
ENG*
[ 0 to 100 / 38 /
0.1deg ]
ENG*
[ 0 to 100 / 2 / 0.1deg ]
ENG*
[ 0 to 900 / 0 / 1sec ]
ENG*
[ 0 to 60 / 10 /
0.1min. ]