Ricoh MP C307 Field Service Manual page 1189

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

6800F0(H) - User parameter switch 32 (SWUSR_20)
Bit 0: Quotation priority for a destination when there is no destination of the specified type
0: Paper output priority = Priority order: 1. IP-fax destination, 2. Fax Number, 3. E-mail address, 4. Folder
1: Electric putout order = Priority order: 1. E-mail address, 2. Folder, 3. IP-fax destination, 4. Fax number
Bits 1 to 7: Not used
6800F1(H) - User parameter switch 33 (SWUSR_21): Not used
6800F2(H) - User parameter switch 34 (SWUSR_22)
Bit 0: Gatekeeper server used with IP-Fax 0: Disabled, 1: Enabled
Bit 1: SIP server used with IP-Fax 0: Disabled, 1: Enabled
Bits 2 to 7: Not used
6800F3(H) - User parameter switch 35 (SWUSR_23)
Redial interval when sending a backup file
6800F4(H) - User parameter switch 36 (SWUSR_24)
Maximum number of redials when sending a backup file
6800F5(H) - User parameter switch 37 (SWUSR_25)
Bit 0: Whether to stop sending a backup file if the destination folder becomes full while the machine is sending or
waiting to send a fax or the backup file. 0: No, • 1: Yes
Bit 2 and 3: Backup file is printed along with the TX communication failure report when a backup file
transmission failure occurs. 00: Do not print, 01: Print first page only, 10: Print whole file
Bit 4: Display the sender's information in the file name of documents that are forwarded to folder destinations. 0:
Disabled, 1: Enabled
Bit 5: Limit the file names of documents that are forwarded to folder destinations to plain characters only. 0:
Disabled, 1: Enabled
Bit 6: When using the remote fax function, the sub-machine beeps to let you know when it has printed a received
document (If you specify "On", the machine will beep according to the setting of [Panel Key Sound] under
[System Settings].) 0: On, 1: Off
Bit 7: Not used
6800F6(H) - User parameter switch 38 (SWUSR_26)
Maximum number of transmissions the machine attempts before determining that a fax cannot be forwarded from
a sender (including special senders) to a folder destination
6800F7(H) - User parameter switch 39 (SWUSR_27)
Interval (in minutes) between resend attempts after failing to forward a fax from a sender (including special
senders) to a folder destination
6800F8(H) - User parameter switch 40 (SWUSR_28)
Bit 0: When memory space is insufficient, the machine prints and then deletes the oldest faxes, creating memory
space for storage of new faxes. 0: Disabled, 1: Enabled
Bit 1 to 7: Not used
6800FD(H) - User parameter switch 45 (SWUSR_2D)
Bit 0 and 1:
4.Service Tables