Ricoh MP C307 Field Service Manual page 1144

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

4.Service Tables
1: Enabled
* This setting can be used for the client machine which has no FCU.
System Switch 1A (SP No. 1-101-027)
No Function
0
LS RX memory capacity
to
threshold setting
7
00-FF (0-1020 Kbyte:
Hex)
System Switch 1B - Not used (do not change these settings)
System Switch 1C - Not used (do not change these settings)
System Switch 1D (SP No. 1-101-030)
No
Function
0
RTI/CSI/CPS code
display
0: Enable
1: Disable
1-
Not used
7
System Switch 1E (SP No. 1-101-031)
No
Function
0
Communication after the Journal
data storage area has become full
0: Impossible
1: Possible
1*
Action when the SAF memory
has become full during scanning
62
"Original 2" can be selected in addition to the "Text", "Text/Photo" and
"Photo" modes.
Comments
Sets the value to x4KB. When the amount of available memory drops below
this setting, RX documents are printed to conserve memory.
Initial setting 0x80 (512 KB)
NOTE: If a customer wants available memory size to be larger, decrease
this threshold
Comments
0: RTI, CSI, CPS codes are displayed on the top line of the LCD panel during
communication.
1: Codes are switched off (no display)
Do not change these settings.
Comments
0: When this switch is on and the journal history becomes full, the
next report prints. If the journal history is not deleted, the next
transmission cannot be received. This prevents overwriting
communication records before the machine can print them.
1: If the buffer memory of the communication records for the Journal
is full, fax communications are still possible. But the machine will
overwrite the oldest communication records.
This setting is effective only when Automatic Journal
printout is enabled but the machine cannot print the report
(e.g., no paper).
0: If the SAF memory becomes full during scanning for a memory
transmission, the successfully scanned pages are transmitted.