Test pattern check
After Executing SP2-111-003
Result: "1" in SP2-194-007
One of results: "5" (Out of adjustable range) in SP2-194-010, -011, -012, -013
The main scan registrations of M, C, Y, K are shifted by more than
±15.
The sub scan registrations of M, C, Y, K are shifted by more than
±20.
The main scan registration is shifted by more than ±0.66 mm, but
only at the central area of the image on the output.
The skew for M, C, Y, K is more than ±0.75 mm.
Others
504
3.
Replace the BiCU.
Test pattern check
Possible cause/Countermeasure
Possible cause/Countermeasure
Defective laser unit
Defective BiCU
1.
Perform the color skew adjustment
(Image Adjustment).
2.
Replace the laser unit.
3.
Replace the BiCU.
Defective image transfer belt
Defective drive units
Defective BiCU
1.
Replace the image transfer belt.
2.
Replace the drum motor.
3.
Replace the BiCU.
Defective ID sensor at center
Deformed center area on the image
transfer belt
Defective BiCU
1.
Replace the ID sensor.
2.
Replace the image transfer belt.
3.
Replace the BiCU.
Defective PCDU
Defective laser optics housing unit
Defective BiCU
1.
Perform the color skew adjustment
(Image Adjustment).
2.
Reinstall or replace the PCDU.
3.
Replace the laser optics housing unit.
4.
Replace the BiCU.
Skew correction upper limit error
Defective BiCU
Defective laser optics housing unit
1.
Perform the color skew adjustment
(Image Adjustment).