23. Position the left hand control rod ball joint to the
pump control arm. Install a bolt, washer and nut
securing the left hand control rod assembly to the
pump control arm (Fig. 281).
Note: The washer is installed between the ball joint
and the control arm.
Fig 281
24. Position the right hand control rod ball joint to the
pump control arm. Install a bolt, washer and nut
securing the right hand control rod assembly to the
pump control arm (Fig. 282).
Note: The washer is installed between the ball joint
and the control arm.
Fig 282
Z580/Z589 DFI Z Master Service Manual
HYDRAULIC SYSTEM
25. Apply anti-seize compound onto the pump input
shaft (Fig. 283).
26. Install the key into the pump shaft keyway (Fig. 284).
PICT-3196a
PICT-3195a
Fig 283
IMG-0444a
Fig 284
IMG-0446a