:DIAGnostic:TEST:CARD:CLEar
:DIAGnostic:TEST:CARD:CLEar
This command clears the relay test result (pass/fail result) of the specified card.
:DIAGnostic:TEST:CARD:CLEar card_number
Parameter
card_number
OUTPUT @Hp5250;":DIAG:TEST:CARD:CLE 1"
:DIAGnostic:TEST:CARD[:EXECute]?
This command executes the relay test for specified card, then returns the pass/fail
result. For more info, see Chapter 3.
You must attach the relay test adapter before executing this command.
This command changes all settings of card to same state as after executing
:SYST:CPON command.
:DIAGnostic:TEST:CARD[:EXECute]? card_number
Parameter
card_number
test_result <newline><^END>
1 : Fail card exists
0 : Pass
OUTPUT @Hp5250;":DIAG:TEST:CARD? ALL"
7-16
Explanation
card number: 1, 2, 3, 4, or ALL