Nortel DMS-100 Series Maintenance Manual page 73

Outside plant access cabinet (opac)
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

define the window size
define how many LCM-level tests, described here, run at the same time
The following are descriptions of these parameters:
BICRELAY_XLCM_TEST_SCHEDULE
— This parameter defines the start time (BRTST_START_TIME) and
stop time (BRTST_STOP_TIME) for the office-level test. These
times cannot be the same. The test window must be a minimum of
10 min long. The last field of this parameter
(BRTST_DAYS_OF_TST) specifies the day or days of the week
when the office-level test runs (MON, TUE, WED, THU, FRI, SAT,
SUN). You can datafill a maximum of seven days in any
combination. You cannot datafill the same day more than one time.
— If the start and stop times are the same, the system displays an error
message. The system also diplays an error message if the test
window is less than 10 min.
— If you try to make a change during the defined test window during
the test, the system displays a message. This message indicates that
you can use the command string BICRELAY OFF to stop the BRT.
You can make changes and use the command string BICRELAY ON
to restart the BRT.
BICRELAY_NUM_SIMUL_TESTS
— This parameter indicates the number of LCM-level tests to run at the
same time.
— The parameter plus the start and stop times of
BICRELAY_XLCM_TEST_SCHEDULE configure the number of
LCMs being tested.
— If you try to make a change during the defined test window during
the test, the system displays a message. This message indicates that
you must wait until the test stops. If the change is required
immediately, you can use the command string BICRELAY OFF at
the command interpreter (CI) level to stop the BRT. You can make
the necessary changes and use the command string BICRELAY ON
to restart the BRT.
DMS-100 Family OPAC Maintenance Manual XPM12 and up
Maintenance overview 1-57